[D /WizardPages [A ] /WizardValues [A [D /Name 'Motor_PreName' /Caption 'Motor' /Type 'STRING' /Value 'P01-23x80@/' ] [D /Name 'StatorSliderID' %/Caption 'Motor' /Type 'STRING' /Value 'P01-23x80/' ] [D /Name 'Stator_ArtNr' /CaptionKeyWord 'Article_Number' /Type 'STRING' /ShowWithCompanyPrefix #1 /Value '0150-1201' ] [D /Name 'P_GainSoft' /Caption 'Default P Gain' /Type 'DOUBLE' /Value 2000.0 /UUID 18 ] [D /Name 'D_GainSoft' /Caption 'Default D Gain' /Type 'DOUBLE' /Value 4.0 /UUID 19 ] [D /Name 'P_GainStiff' /Caption 'Default P Gain Stiff' /Type 'DOUBLE' /Value 5000.0 /UUID 18 ] [D /Name 'D_GainStiff' /Caption 'Default D Gain Stiff' /Type 'DOUBLE' /Value 10.0 /UUID 19 ] ] %************************************************************************************************* /MCParameters [A [D /Name 'ADF_Name' /TreeUPID 6220 /Type 'STRING' /DefValue 'PS01-23x80-XX_V3S3' ] [D /Name 'Stator_Type_Code' /TreeUPID 4613 /Type 'DOUBLE' /DefValue 1.0 ] [D /Name 'Coil_Resistance' /CaptionKeyWord 'Phase_Resistance' /TreeUPID 4511 /Type 'DOUBLE' /DefValue 10.1 ] [D /Name 'Coil_Inductivity' /TreeUPID 4512 /Type 'DOUBLE' /DefValue 0.0014 ] [D /Name 'Maximal_Current' /TreeUPID 4510 /Type 'DOUBLE' /DefValue 4.0 /OnChange [A [D /Name 'CalculateControlParameters' ] ] ] [D /Name 'MotSen_FFT_C1' /TreeUPID 4521 /Type 'DOUBLE' /DefValue 0.939238 ] [D /Name 'MotSen_FFT_C3' /TreeUPID 4522 /Type 'DOUBLE' /DefValue -0.054884 ] [D /Name 'MotSen_FFT_C5' /TreeUPID 4523 /Type 'DOUBLE' /DefValue 0.005318 ] [D /Name 'MotSen_FFT_C7' /TreeUPID 4524 /Type 'DOUBLE' /DefValue -0.000498 ] [D /Name 'MotSen_FFT_C9' /TreeUPID 4525 /Type 'DOUBLE' /DefValue 0.000062 ] [D /Name 'CrossCoupling_PH1_Sine' /TreeUPID 4580 /DefValue -0.027 /Type 'DOUBLE' ] [D /Name 'CrossCoupling_PH1_Cosine' /TreeUPID 4581 /DefValue -0.002 /Type 'DOUBLE' ] [D /Name 'CrossCoupling_PH2_Sine' /TreeUPID 4582 /DefValue 0.0025 /Type 'DOUBLE' ] [D /Name 'CrossCoupling_PH2_Cosine' /TreeUPID 4583 /DefValue 0.018 /Type 'DOUBLE' ] [D /Name 'Com_FFT_C1' /TreeUPID 4531 /DefValue 1.04942 /Type 'DOUBLE' ] [D /Name 'Com_FFT_C3' /TreeUPID 4532 /DefValue -0.000211 /Type 'DOUBLE' ] [D /Name 'Com_FFT_C5' /TreeUPID 4533 /DefValue -0.052679 /Type 'DOUBLE' ] [D /Name 'Com_FFT_C7' /TreeUPID 4534 /DefValue 0.000411 /Type 'DOUBLE' ] [D /Name 'Com_FFT_C9' /TreeUPID 4535 /DefValue 0.00346 /Type 'DOUBLE' ] [D /Name 'Com_BackEMF_C1' /TreeUPID 4541 /DefValue 0.952705 /Type 'DOUBLE' ] [D /Name 'Com_BackEMF_C3' /TreeUPID 4542 /DefValue -0.047825 /Type 'DOUBLE' ] [D /Name 'Com_BackEMF_C5' /TreeUPID 4543 /DefValue -0.000154 /Type 'DOUBLE' ] [D /Name 'Com_BackEMF_C7' /TreeUPID 4544 /DefValue 0.00074 /Type 'DOUBLE' ] [D /Name 'Com_BackEMF_C9' /TreeUPID 4545 /DefValue 0.000364 /Type 'DOUBLE' ] [D /Name 'Slider_MainID' /TreeUPID 6202 /Type 'ENUM' /StartWithTreeValue #1 /ENumDef [A [D /Value $0101 /OnSelect [A [D /Name 'Motor_FactorPerPolePitch' /Value 1.38 ] ] ] [D /Value $0102 /OnSelect [A [D /Name 'Motor_FactorPerPolePitch' /Value 1.38 ] ] ] [D /Value $0103 /OnSelect [A [D /Name 'Motor_FactorPerPolePitch' /Value 1.76502 ] ] ] [D /Value $0104 /OnSelect [A [D /Name 'Motor_FactorPerPolePitch' /Value 1.588518 ] ] ] [D /Value $0105 /OnSelect [A [D /Name 'Motor_FactorPerPolePitch' /Value 1.38 ] ] ] ] ] [D /Name 'StatorSubType' /TreeUPID 4614 /Type 'ENUM' /DefValue -1 /DefValueIfNotInTree 0 % This parameter is new. If not found in tree, then set standard stator /StartWithTreeValue #1 /OnChange [A [D /Name 'CalculateMotorProperty'] %[D /Name 'Module_BuildActuatorName'] [D /Name 'CalculateFFValues' ] [D /Name 'CalculateStrokeRange' ] ] /ENumDef [A [D /Value $4010101 /Caption 'PS01-23x80' /ShowWithCompanyPrefix #1 /OnSelect [A [D /Name 'Stator_Name' /Value 'PS01-23x80' ] [D /Name 'StatorInfoBlock_ArtNr' /Value 1201 ] [D /Name 'Stator_ArtNr' /Value '0150-1201' ] [D /Name 'Stator_Length' /Value 0.177 ] [D /Name 'Stator_Mass' /Value 0.265 ] [D /Name 'Motor_Name_Extension' /Value ''] ] ] [D /Value $4030101 /Caption 'PS01-23x80-R' /ShowWithCompanyPrefix #1 /OnSelect [A [D /Name 'Stator_Name' /Value 'PS01-23x80-R' ] [D /Name 'StatorInfoBlock_ArtNr' /Value 1233 ] [D /Name 'Stator_ArtNr' /Value '0150-1233' ] [D /Name 'Stator_Length' /Value 0.162 ] [D /Name 'Stator_Mass' /Value 0.265 ] [D /Name 'Motor_Name_Extension' /Value '-R'] ] ] [D /Value $4040101 /Caption 'PS01-23x80-R20' /ShowWithCompanyPrefix #1 /OnSelect [A [D /Name 'Stator_Name' /Value 'PS01-23x80-R20' ] [D /Name 'StatorInfoBlock_ArtNr' /Value 1241 ] [D /Name 'Stator_ArtNr' /Value '0150-1241' ] [D /Name 'Stator_Length' /Value 0.177 ] [D /Name 'Stator_Mass' /Value 0.265 ] [D /Name 'Motor_Name_Extension' /Value '-R20'] ] ] ] ] [D /Name 'Move_Part' /TreeUPID 6204 /Type 'ENUM' /DefValue 0 /StartWithTreeValue #1 /OnChange [A [D /Name 'CalculateFFValues' ] ] /ENumDef [A [D /Value 0 /CaptionKeyWord 'Slider' /OnSelect [A ] ] [D /Value 1 /CaptionKeyWord 'Stator' /OnSelect [A ] ] [D /Value 2 /CaptionKeyWord 'Stator+PF01-23x50' /OnSelect [A ] ] ] ] [D /Name 'Total_Load_Mass' % new parameter since 3.7 (used e.g. for MPC Move calculation) /TreeUPID 6240 /OnChange [A ] /Type 'DOUBLE' ] [D /Name 'P_Gain_SetA' /TreeUPID 5026 /StartWithTreeValue #1 /DefValue 2000.0 /Type 'DOUBLE' ] [D /Name 'D_Gain_SetA' /TreeUPID 5027 /StartWithTreeValue #1 /DefValue 4.0 /Type 'DOUBLE' ] [D /Name 'TempModelPar_MaxWindingTemp' /TreeUPID 4612 /Type 'DOUBLE' ] [D /Name 'Warn_Temp' /TreeUPID 4610 %/Caption 'Warning Temperature' /DefValue 110.0 /Type 'DOUBLE' ] [D /Name 'Error_Temp' /TreeUPID 4611 /DefValue 120.0 /Type 'DOUBLE' ] [D /Name 'Temp_Sens_Warning_Temp' /TreeUPID 4689 /Type 'DOUBLE' /DefValue 80.0 ] [D /Name 'Temp_Sens_Error_Temp' /TreeUPID 4690 /Type 'DOUBLE' /DefValue 90.0 ] ] ]